home *** CD-ROM | disk | FTP | other *** search
/ Atari Forever 4 / Atari Forever 4.zip / Atari Forever 4.iso / SERIE_S / S_904 / MAGNUM / NICKEL.TXT < prev    next >
Text File  |  1998-03-14  |  1KB  |  32 lines

  1. For the determination of nickel in waste water a calibration
  2. line is made.
  3.  
  4. The analist makes soultions with concentrations of respectively
  5. 0, 0.1, 0.2, 0.3, 0.4, 0.5 and 0.6 mg/l nickel.
  6.  
  7. Then he measured the extinctions of the solutions. He measured:
  8.  
  9. concentration nickel  |  extinction
  10. ----------------------|--------------
  11.          0            |     0.064
  12.          0.1          |     0.15
  13.          0.2          |     0.26
  14.          0.3          |     0.32
  15.          0.4          |     0.43
  16.          0.5          |     0.48
  17.          0.6          |     0.53
  18.  
  19. Now he will calculate the best funtion trough the points.
  20. He used the first orer polynom and shows the residue plot.
  21. In the residue plot is to see that the first two residues
  22. are lying below 0. He decided to use the second order
  23. polynoom the residue plot shows now a random plot.
  24.  
  25. If you use magic numbers for polynom regression look always
  26. to the residue plot, it is important that the residues are random.
  27.  
  28. In the future Magic numbers make ik possible to use the Goodness of Fit
  29. test. With this test the significancy of a model can be indicated.
  30.  
  31.  
  32.